Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 210
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38599688

RESUMO

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
EuroIntervention ; 20(8): e487-e495, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38629416

RESUMO

BACKGROUND: Data on the likelihood of left ventricle (LV) recovery in patients with severe LV dysfunction and severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and its prognostic value are limited. AIMS: We aimed to assess the likelihood of LV recovery following TAVI, examine its association with midterm mortality, and identify independent predictors of LV function. METHODS: In our multicentre registry of 17 TAVI centres in Western Europe and Israel, patients were stratified by baseline LV function (ejection fraction [EF] >/≤30%) and LV response: no LV recovery, LV recovery (EF increase ≥10%), and LV normalisation (EF ≥50% post-TAVI). RESULTS: Our analysis included 10,872 patients; baseline EF was ≤30% in 914 (8.4%) patients and >30% in 9,958 (91.6%) patients. The LV recovered in 544 (59.5%) patients, including 244 (26.7%) patients whose LV function normalised completely (EF >50%). Three-year mortality for patients without severe LV dysfunction at baseline was 29.4%. Compared to this, no LV recovery was associated with a significant increase in mortality (adjusted hazard ratio 1.32; p<0.001). Patients with similar LV function post-TAVI had similar rates of 3-year mortality, regardless of their baseline LV function. Three variables were associated with a higher likelihood of LV recovery following TAVI: no previous myocardial infarction (MI), estimated glomerular filtration rate >60 mL/min, and mean aortic valve gradient (mAVG) (expressed either as a continuous variable or as a binary variable using the standard low-flow, low-gradient aortic stenosis [AS] definition). CONCLUSIONS: LV recovery following TAVI and the extent of this recovery are major determinants of midterm mortality in patients with severe AS and severe LV dysfunction undergoing TAVI. Patients with no previous MI and those with an mAVG >40 mmHg show the best results following TAVI, which are at least equivalent to those for patients without severe LV dysfunction. (ClinicalTrials.gov: NCT04031274).


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Disfunção Ventricular Esquerda , Humanos , Valva Aórtica/cirurgia , Ventrículos do Coração , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Estudos Multicêntricos como Assunto , Estudos Clínicos como Assunto
3.
Int J Cardiol ; : 131934, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38437953

RESUMO

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.

6.
ESC Heart Fail ; 11(2): 1218-1227, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38303542

RESUMO

AIMS: Acute mitral regurgitation (MR) in the setting of myocardial infarction (MI) may be the result of papillary muscle rupture (PMR). This condition is associated with high morbidity and mortality. We aim to evaluate the feasibility of transcatheter edge-to-edge mitral valve repair (TEER) in this acute setting. METHODS AND RESULTS: We analysed data from the International Registry of MitraClip in Acute Mitral Regurgitation following acute Myocardial Infarction (IREMMI) of 30 centres in Europe, North America, and the middle east. We included patients with post-MI PMR treated with TEER as a salvage procedure, and we evaluated immediate and 30-day outcomes. Twenty-three patients were included in this analysis (9 patients suffered complete papillary muscle rupture, 9 partial and 5 chordal rupture). The patients' mean age was 68 ± 14 years. Patients were at high surgical risk with median EuroSCORE II 27% (IQR 16, 28) and 20 out of 23 (87% were in cardiogenic shock). All patients were treated with vasopressors, and 17 out of 23 patients required mechanical support. TEER procedure was performed on the median 6 days after the index MI date IQR (3, 11). Procedural success was achieved in 87% of patients. The grade of MR was significantly decreased after the procedure. MR reduction to 0 or 1 + was achieved in 13 patients (57%), to 2 + in 7 patients (30%), P < 0.01. V-Wave was reduced from 49 ± 8 mmHg to 26 ± 10 mmHg post-procedure, P < 0.01. Sixteen out of 23 patients (70%) were discharged from hospital and 5 of them required reintervention with surgical mitral valve replacement. No additional death at 1 year was documented. CONCLUSIONS: TEER is a feasible therapy in critically ill patients with PMR due to a recent MI. TEER may have a role as salvage treatment or bridge to surgery in this population.


Assuntos
Insuficiência da Valva Mitral , Infarto do Miocárdio , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Músculos Papilares , Infarto do Miocárdio/complicações , Choque Cardiogênico/etiologia
7.
Eur Heart J ; 45(11): 922-936, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38243773

RESUMO

BACKGROUND AND AIMS: Risk stratification for mitral valve transcatheter edge-to-edge repair (M-TEER) is paramount in the decision-making process to appropriately select patients with severe secondary mitral regurgitation (SMR). This study sought to develop and validate an artificial intelligence-derived risk score (EuroSMR score) to predict 1-year outcomes (survival or survival + clinical improvement) in patients with SMR undergoing M-TEER. METHODS: An artificial intelligence-derived risk score was developed from the EuroSMR cohort (4172 and 428 patients treated with M-TEER in the derivation and validation cohorts, respectively). The EuroSMR score was validated and compared with established risk models. RESULTS: The EuroSMR risk score, which is based on 18 clinical, echocardiographic, laboratory, and medication parameters, allowed for an improved discrimination of surviving and non-surviving patients (hazard ratio 4.3, 95% confidence interval 3.7-5.0; P < .001), and outperformed established risk scores in the validation cohort. Prediction for 1-year mortality (area under the curve: 0.789, 95% confidence interval 0.737-0.842) ranged from <5% to >70%, including the identification of an extreme-risk population (2.6% of the entire cohort), which had a very high probability for not surviving beyond 1 year (hazard ratio 6.5, 95% confidence interval 3.0-14; P < .001). The top 5% of patients with the highest EuroSMR risk scores showed event rates of 72.7% for mortality and 83.2% for mortality or lack of clinical improvement at 1-year follow-up. CONCLUSIONS: The EuroSMR risk score may allow for improved prognostication in heart failure patients with severe SMR, who are considered for a M-TEER procedure. The score is expected to facilitate the shared decision-making process with heart team members and patients.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/cirurgia , Inteligência Artificial , Coração , Ecocardiografia , Fatores de Risco , Resultado do Tratamento
8.
JACC Cardiovasc Interv ; 17(3): 374-387, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38180419

RESUMO

BACKGROUND: The COVID-19 pandemic adversely affected health care systems. Patients in need of transcatheter aortic valve replacement (TAVR) are especially susceptible to treatment delays. OBJECTIVES: This study sought to evaluate the impact of the COVID-19 pandemic on global TAVR activity. METHODS: This international registry reported monthly TAVR case volume in participating institutions prior to and during the COVID-19 pandemic (January 2018 to December 2021). Hospital-level information on public vs private, urban vs rural, and TAVR volume was collected, as was country-level information on socioeconomic status, COVID-19 incidence, and governmental public health responses. RESULTS: We included 130 centers from 61 countries, including 65,980 TAVR procedures. The first and second pandemic waves were associated with a significant reduction of 15% (P < 0.001) and 7% (P < 0.001) in monthly TAVR case volume, respectively, compared with the prepandemic period. The third pandemic wave was not associated with reduced TAVR activity. A greater reduction in TAVR activity was observed in Africa (-52%; P = 0.001), Central-South America (-33%; P < 0.001), and Asia (-29%; P < 0.001). Private hospitals (P = 0.005), urban areas (P = 0.011), low-volume centers (P = 0.002), countries with lower development (P < 0.001) and economic status (P < 0.001), higher COVID-19 incidence (P < 0.001), and more stringent public health restrictions (P < 0.001) experienced a greater reduction in TAVR activity. CONCLUSIONS: TAVR procedural volume declined substantially during the first and second waves of the COVID-19 pandemic, especially in Africa, Central-South America, and Asia. National socioeconomic status, COVID-19 incidence, and public health responses were associated with treatment delays. This information should inform public health policy in case of future global health crises.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Pandemias , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , COVID-19/epidemiologia , Sistema de Registros , Fatores de Risco
9.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-37624856

RESUMO

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Resultado do Tratamento , Cateterismo Cardíaco
10.
JACC Cardiovasc Interv ; 17(1): 60-72, 2024 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-38069986

RESUMO

BACKGROUND: Several orthotopic transcatheter strategies have been developed to treat severe tricuspid regurgitation (TR); however, many patients are deemed unsuitable. Caval valve implantation with the TricValve system addresses this unmet need. OBJECTIVES: This study sought to determine the impact of TricValve on systemic congestion and quality of life (QOL) at 1 year. METHODS: The TRICUS (Safety and Efficacy of the TricValve® Transcatheter Bicaval Valves System in the Superior and Inferior Vena Cava in Patients With Severe Tricuspid Regurgitation) and TRICUS EURO studies were prospective, nonblinded, nonrandomized, single-arm trials representing the early-in-man experience of the TricValve system in NYHA functional class III or IV severe TR patients, optimally medicated and ineligible for open heart surgery, with significant caval backflow. The primary endpoint was QOL metrics and functional status. The 1-year results of the combined cohort are described here. RESULTS: Forty-four patients were included. Mean age was 76.2 ± 7.5 years, 81.0% were women, and the TRISCORE (risk score model for isolated tricuspid valve surgery) was 5.3 ± 1.3. Clinical improvement at 1 year was achieved in 42 (95.5%) patients, measured by (at least 1 of) an increase in ≥15 points from baseline in 12-item Kansas City Cardiomyopathy Questionnaire score, improvement to NYHA functional class to I or II, or an increase ≥40 m in the 6-minute walk test. There were 3 (6.8%) deaths at 1-year follow-up (1 cardiovascular), and the heart failure rehospitalization rate was 29.5%. Stent fracture, conduction system disturbances, or clinically significant leaflet thrombosis were not detected. Abolished hepatic vein backflow was achieved and persisted in 63.8% of the patients, contributing towards a reduction in congestive symptoms, N-terminal pro-B-type natriuretic peptide levels (P = 0.032), and diuretic treatment. CONCLUSIONS: Caval valve implantation with the TricValve system associated with meaningful 1-year clinical improvements in terms of QOL along with relatively low mortality rates. (TRICUS Study - Safety and Efficacy of the TricValve® Device; NCT03723239).


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Cateterismo Cardíaco , Seguimentos , Estudos Prospectivos , Qualidade de Vida , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
11.
Artigo em Inglês | MEDLINE | ID: mdl-38072288

RESUMO

BACKGROUND: Transcatheter edge-to-edge repair (TEER) for the treatment of tricuspid regurgitation (TR) has experienced fast adoption following commercial approval. Defining the appropriate target population for TEER therapy is important to guide patient selection. The aim of this study was to characterize tricuspid valve anatomy and coaptation gap in subjects receiving TEER for the treatment of TR in a contemporary postmarket setting. METHODS: The bRIGHT study is a prospective, multicenter, single-arm, postmarket study evaluating the safety and effectiveness of the TriClip device. Procedural outcomes included implant success, acute procedural success, TR severity, major adverse events, single-leaflet device attachment, and embolization through 30 postprocedure days. Tricuspid valve characteristics, including morphology, annulus size, and leaflet mobility, were assessed via two-dimensional transesophageal echocardiography from the screening visit by an independent echo core lab to characterize subject variability. Coaptation gap measurements were taken in both the transgastric short-axis (TG SAX) and RV inflow/outflow views. RESULTS: The independent echo core lab performed a detailed assessment of the tricuspid valve on 135 consecutive subjects with available TG SAX views from 24 sites. Tricuspid valve morphologies included 2 to 5 leaflets, with a non-trileaflet valve in 28% of subjects and ≥4 leaflets in 21% of subjects. The etiology of TR was functional in 91% (96/105), mixed in 7% (7/105), and lead induced in 2% (2/105) of subjects. Leaflet mobility was mildly restricted in 69% (78/113) and moderately restricted in 7% (8/113) of subjects. Annulus diameter averaged 4.7 ± 0.7 cm with a range of 2.5 to 6.2 cm. From the TG SAX view, the coaptation gap measured 8.1 ± 3.1 and 5.2 ± 2.3 mm in the central and mid regions of the anterior-septal coaptation line and 6.6 ± 3.2 and 3.8 ± 2.1 mm in the central and mid regions of the septal-posterior coaptation line, respectively. From the right ventricular inflow/outflow view, the coaptation gap measured 4.7 ± 2.4, 5.2 ± 2.4, and 4.6 ± 3.0 mm in the anterior, mid, and posterior regions of the tricuspid valve, respectively. Thirty-day TR reduction (by number of grades) was similar among subjects with coaptation gaps of <7 mm, 7 to 10 mm, and >10 mm. CONCLUSION: A broad range of anatomies was observed in this postmarket population. Characterization of the tricuspid valve and coaptation gap will help to better understand and better define the target patient population for tricuspid TEER therapy.

12.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37905381

RESUMO

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Volume Sistólico , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Insuficiência Cardíaca/etiologia , Função Ventricular Esquerda , Sistema de Registros
14.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480891

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Incidência , Bloqueio de Ramo , Prognóstico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
15.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMO

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Assuntos
Marca-Passo Artificial
16.
JACC Case Rep ; 15: 101848, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37283839

RESUMO

A 79-year-old woman with a history of dilated cardiomyopathy who required a permanent peacemaker, recently upgraded to implantable cardioverter-defibrillator cardiac resynchronization therapy, was admitted for right heart failure. On echocardiography, torrential tricuspid regurgitation was noted, with 2 leads across the valve. After multidisciplinary evaluation, a dedicated transcatheter valve replacement was successfully implanted. (Level of Difficulty: Intermediate.).

17.
J Clin Med ; 12(12)2023 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-37373808

RESUMO

BACKGROUND: The timing and selection of optimal candidates for mitral transcatheter edge-to-edge valve repair remains to be fully determined, especially in cases with severely depressed left ventricular ejection fraction (LVEF). The objective of this study is to evaluate the prognostic value of myocardial strain (LVGLS) in this setting. METHODS: Retrospectively, 172 consecutive patients with LVEF ≤40% and severe MR treated with MitraClip were included. Four groups were generated according to the LVEF (<30% or ≥30%) and median LVGLS. The primary end-point was cardiovascular mortality. RESULTS: Procedural success was high (96.5%) and complications were rare. At one-year follow-up, 82.5% of patients maintained MR grade ≤2, 79.2% were at a NYHA class ≤II and a reduction of 80% in heart failure admissions was observed in all groups. Interestingly, among patients with a more depressed LVEF, LVGLS was found to be an independent predictor for cardiovascular mortality (HR: 3.3; 95% CI: 1.1-10, p = 0.023). CONCLUSIONS: Mitral valve repair with MitraClip is safe and it improves the mid-term functional class of patients regardless of LVEF. LVGLS can help in the selection of optimal candidates and timing for this procedure, as well as in the recognition of those patients with worse prognoses.

18.
EuroIntervention ; 19(4): e340-e351, 2023 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-37334654

RESUMO

BACKGROUND: A small aortic annulus (SAA) is a risk factor for prosthesis-patient mismatch (PPM) in patients undergoing surgical or transcatheter aortic valve implantation (TAVI). Data regarding TAVI in patients with extra-SAA are scarce. AIMS: The aim of this study was to analyse the safety and efficacy of TAVI in patients with extra-SAA. METHODS: A multicentre registry study including patients with extra-SAA (defined as an aortic annulus area <280 mm2 and/or perimeter <60 mm) undergoing TAVI was established. Primary efficacy and safety endpoints were defined as device success and early safety at 30 days, respectively, using the Valve Academic Research Consortium-3 criteria, and were analysed according to valve type: self-expanding (SEV) versus balloon-expandable (BEV). RESULTS: A total of 150 patients were included, of which 139 (92.7%) were women, and 110 (73.3%) received an SEV. Intraprocedural technical success was 91.3%, with a higher rate in patients receiving an SEV (96.4% vs 77.5% with BEV; p=0.001). Overall, 30-day device success was 81.3%, (85.5% with SEV vs 70.0% with BEV; p=0.032). The primary safety endpoint occurred in 72.0% of patients (with no difference between groups; p=0.118). Severe PPM occurred in 12% (9.0% with SEV and 24.0% with BEV; p=0.039), with no impact on all-cause mortality, cardiovascular mortality, or heart failure readmission at 2-year follow-up. CONCLUSIONS: TAVI is a safe and feasible treatment in patients with extra-SAA with a high rate of technical success. The use of SEV was associated with a lower rate of intraprocedural complications, higher device success at 30 days and better haemodynamic outcomes compared to BEV.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento
19.
Int J Cardiol ; 390: 131139, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355239

RESUMO

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Assuntos
Insuficiência Cardíaca , Transplante de Coração , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Volume Sistólico , Função Ventricular Esquerda , Fatores de Tempo , Transplante de Coração/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Sistema de Registros , Implante de Prótese de Valva Cardíaca/métodos
20.
EuroIntervention ; 19(5): e442-e449, 2023 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-37128805

RESUMO

BACKGROUND: Data regarding the safety and long-term effectiveness of percutaneous closure of paravalvular leak (PVL) after transcatheter aortic valve implantation (TAVI) are scarce. AIMS: This study aims to present a large multicentre international experience of percutaneous post-TAVI PVL closure. METHODS: All patients who underwent percutaneous post-TAVI PVL closure in 14 hospitals across Europe and North America between January 2018 and October 2022 were included. RESULTS: Overall, 45 patients (64% male) were enrolled. The median age was 80 years (75-84). Among them, 67% and 33% had self-expanding and balloon-expandable valve implantations, respectively. Baseline post-TAVI PVL was severe in 67% of cases and moderate in the rest. The time from index TAVI to PVL closure procedure was 16.1 (8.7-34.8) months. Most patients were in NYHA Class III and IV (73%) before the procedure, and 40% had referred hospitalisations for heart failure between TAVI and the PVL closure procedure. Successful PVL closure was achieved in 94%, reducing regurgitation to ≤mild in 91% and moderate in the rest. The Amplatzer Valvular Plug III was the most frequently used device (27 cases), followed by the Amplatzer Valvular Plug 4. The incidence of severe adverse events was 11%. None of the patients died during the index hospitalisation. During long-term follow-up (21.7±16.2 months), the all-cause mortality rate was 14%, and patients presented improvement in functional status and a significant reduction in the rate of hospitalisation for heart failure (from 40% to 6%). CONCLUSIONS: Percutaneous PVL closure is a feasible and safe option for treating post-TAVI leaks. Successful PVL reduction to mild or less could be associated with acute and long-lasting improvements in clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso de 80 Anos ou mais , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/métodos , Sistema de Registros , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...